Ground Fault Circuit Breaker Din Rail Mount
Out of stock online.
Ground fault circuit breaker din rail mount. The ndb1l 32c6 120 is a gfci circuit breaker rated 6 amp at 120 volt and is used for general purpose applications. The asi gfci circuit breaker is also referred to as a residual current device rcd or a residual current circuit breaker rccb the ndb1l series is a din rail mounted mcb rcd combination device that protects a circuit and prevents shock hazard. We offer many configurations voltage ranges and current ranges to meet your requirements. Circuit breakers circuit breakers include industrial din rail circuit breakers high density miniature circuit breakers motor circuit protectors residual current devices miniature circuit breakers and supplementary protection devices.
Eaton s din rail mounted accessories are mounted in consumer units and complement mcb and rcd circuit protection devices to fulfill all functions of end distribution at the consumer unit. Also known as iec miniature circuit breakers modular din rail breakers or dual rated ul and iec breakers they mount on din rails to save space in panelboards and load centers. These gfci or rcd circuit breakers are capable of sensing earth leakage current and interrupting the circuit automatically when the current exceeds a. Out of stock online.
The ul1053 ground fault breaker opens the circuit with leakage greater then 30 ma and has a convenient led visual trip indicator. Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit. 63 amp single pole circuit breaker din rail mount 240vac 60vdc model ndb2 63c63 1 18 41 18 41. Set your store to see local availability view similar in stock.
Miniature circuit breakers faz series for control panels. Mount directly to din rail. This din rail mounted circuit breaker operates on a c trip curve and protects against short circuits overloads and has an earth leakage interrupt capacity of 30ma. Abb f202ac 63 0 03 breaker din rail mount ground fault residual current 30ma 63a.
All are thermal magnetic breakers trip when heat is generated by sustained low level overload current but will trip quickly when the magnetic field in the coil senses a high current short circuit. The asi ndb1l 32c 20 120v is a din rail mounted ground fault circuit breaker that provides short circuit overload and earth leakage protection to equipment. Asi 25 amp 240 volt 1 pole gfci circuit breaker din rail mount model ndb1l 32c 25 240v 34 92 34 92.