Gravity Roof Vent For Elevator Shaft
Ul listed this gravity roof vent is rated to withstand wind pressures of over 50 psf which is equivalent to wind speeds exceeding 200 mph.
Gravity roof vent for elevator shaft. A built in curb cap offers prepunched holes to help provide for easy attachment to the roof curb. 3004 5 1 vents in the hoistway enclosures. Low profile gravity roof vents feature corrosion resistant weather resistant rigid aluminum construction and include integral bird screens. Lsug is a low silhouette gravity relief upblast ventilator designed for use on vertical high velocity exhaust systems.
Gravity ventilators are designed to provide relief exhaust and intake supply airflow for a number of commercial and light industrial applications. According to code elevator shafts hoistways meeting certain requirements must be adequately ventilated. Engineered and certified for both flat roof ventilation and steep slope ventilation the aura gravity ventilator is available for both residential and commercial buildings. Vent shown in image features a pv 24 c06 277 00 a large pop vent.
Our elevator vent is an economical easily installed solution for any elevator shaft or machine room application. The gravity intake and relief ventilators are non powered do not have a fan and work on pressure differential between the inside and outside of the building. Throat size 4 5 6 7 8 9 10 12 14 15 16 18 20 24 30. The vents in the side of the hoistway enclosure below the elevator machine room floor or in the roof of the hoistway shall open either directly to the outer air or through noncombustible ducts to the outer air.
Lsug units include damper doors and a high volume rain gutter to prevent water infiltration. Depending on the architecture of the building roof these vents were sometimes hard to hide. Lsug units are available in 7 sizes from 24 to 60 inches. Hoistways of elevators and dumbwaiters penetrating more than three.
2009 ibc 3004 1 hoistway venting required. The pul air is available in galvanized steel aluminum stainless steel or copper construction. The rational for having venting originally according to the code commentary was that most fire deaths occur due to smoke which could rise up the elevator shaft. Size 4 5 6 7 8 9 10 12 14 15 16 18 20 24 30 a dia.
Given an elevator shaft serving four 4 stories with three 3 floor ceiling penetrations question is a smoke vent required at the top of the elevator shaft. Shop for a gravity roof vent from grainger in either hooded or low profile design. Gravity ventilators gravity intake and relief ventilators for use in non powered applications.